Medzer Infusion Pump provide reliable and precise solution for controlled medication delivery. They support various infusion modes to meet different medical needs. Their user-friendly interface ensure easy programming and monitoring. With advanced accuracy and consistent performance, they enhance patient care and treatment efficiency. The compact, lightweight design make them ideal for bedside use in hospitals and clinics. Our infusion pump offer accurate medication delivery that ensure both patient safety and healthcare efficiency.
Reservoir Capacity: Dose Volume : 305 units
Display: 128 × 64 LCD screen
Temporary Basal rates: ± up to 200 % in 10 % increments available for 24 hours
Basal setting: 20 unit (Default)
VTBI: 1 ~ 9999 ml
Pumping Mechanism: Curvilinear peristaltic
IV Set: Standard enteral feeding set
Infusion Mode: Continuous: Constantly feed according to VTBI
Flow Rate: 1ml/h ~ 2000 ml/h (in 1,5,1 ml/h increments)
VTBI: 1 ~ 9999 ml(in 1,5,1 ml/h increments)
Purge: 600 ~ 2000 ml/h(in 1,5,1 ml/h increments)
Bolus: 600 ~ 2000 ml/h(in 1,5,1 ml/h increments)
Flow Rate: 1ml/h ~ 500ml/h, 1ml/h increment
VTBI: 0.1 ~ 9999ml or Empty
Purge: 500ml/h
Bolus: 500ml/h
Flow Rate: 1ml/h ~ 400ml/h, step by 1ml/h
VTBI: 0 ~ 9999, step by 1 ml
Purge: 2000 ±10% ml/h
Bolus: 2000 ±10% ml/h
Flow Rate: 1 ml/h ~ 300 ml/h
VTBI: 0.1ml~999ml,≤±10%
Pumping Mechanism: Peristaltic pump
IV Set: Special feeding tube
Flow Rate: 1ml/h-400ml/h, step by 1ml/h
VTBI: Basic : 0 ~ 9999ml
Bolus: 400 ml/h
IV Set: Dedicated nutrition IV sets
Material: PVC
Tubing: transparent/ translucent
Vented spike: 20 drops-ml with air vent
Drip chamber Size: 4.8 × 12.8 mm
Reservoir Capacity: 100ml, 150ml, 200ml, 250ml, 275ml, 350ml
Flow Rate: Dose: 0 - 50 (0-10,increment by 0.1;10-50,increment by1)
Pumping Mechanism: Continuous or Intermittent
Battery: AAA alkaline battery
Flow rate range:
0.1 to 1500 ml/h
0.1 to 100 ml/h (increment 0.1 ml/h)
101 to 1500 ml/h (increment 1 ml/h)
Volume to be Infused (VIBI):
0.1 to 9999 ml/h
0.1 to 999.9 ml/h (increment 0.1 ml/h)
1000 to 9999 ml/h (increment 1 ml/h)
Purge Rate: 1000 ml/h
KVO Rate: 2.5 ml/h
Screen: 4.3inch LCD color touch screen
Occlusion Levels: 12 levels (selectable)
Memory storage: Greater than 5000 entries
Infusion Modes: ml/h (Rate, Time), Body Weight, Drip, Loading-dose, Ramp up/down, Sequence, Drug Library
Flow Rate: 1-1200 ml/h (in 0.1 ml/h increments)
VTBI: 1 ~ 20000 ml (in 0.1 ml increments)
Purge: 500, 800, 1200 ml/h
Bolus: 500, 800, 1200 ml/h
Flow Rate: 1ml/h ~ 2000ml/h ; 0.1ml
VTBI: 0.1ml/h~9999.9ml/h (“0” for turning off the setting function of the volume limit )
Bolus: 1000ml/h
Infusion Mode: Rate mode
Infusion rate: ml/h mode: 1-1200 ml/h d/min mode: 1-266 d/min
Unit conversion: d/min and ml/h unit can be converted
FF rate: 100 -1200 ml/h (100 ml/step)
KVO rate: 1 - 5.0ml/h
2025 © All Rights Reserved by Medzer.com