Cardiotocography Machine

Medzer Cardiotocography (CTG) Machine are designed to monitor fetal heart rate and uterine contractions with precision. They feature advanced sensors and high-resolution display that provide clear, accurate readings in real-time. Their compact, durable design make them suitable for both hospital and clinic use. With user-friendly controls and data storage capabilities, they allow for easy analysis and report generation. Our cardiotocography machine ensure the safety and well-being of both mother and baby.

Ultrasonic Fetal Monitor UFM-1000A

FHR Range: 50 to 240 bpm

FHR Accuracy: ± 2 bpm

Parameters: FHR1, FHR2

Sweep Speed: X1, X2, X4, X8

Ultrasonic Fetal Monitor UFM-1000B

FHR: Transducer: Multi-crystals, pulsed doppler, high sensitively


Strength: ,< 5mW/cm2
Working frequency: 1.0 MHz
Signal processing: special DSP system and modern recognization
Measurement range: 50 bpm ~ 210 bpm

TOCO Pressure: Range: 0 ~ 100 units

Maternal ECG: Measure scope: 30 bpm ~ 240 bpm


Measure accuracy: ±2 bpm

NIBP measurement: a) NIBP-SYS (6.7~32.0Kpa)(50~240mmHg)


b) NIBP-DIA (3.4~26.6Kpa)(25~200mmHg)
c) NIBP-MEAN(2.0~24.0ka(15~180mmHg)

Ultrasonic Fetal Monitor UFM-1000C

FHR: Transducer: Multi-crystals, pulsed doppler


Strength: < 5 mW/cm2
Working frequency: 1.0MHz
Signal processing: special DSP system and modern recognization
Measurement range: 50 bpm ~ 210 bpm

TOCO Pressure: Range: 0 ~ 100 units

Maternal ECG: Measure scope: 30 bpm ~ 240 bpm


Measure accuracy: ±2 bpm

NIBP measurement: a) NIBP-SYS (6.7~32.0Kpa)(50~240mmHg)


b) NIBP-DIA (3.4~26.6Kpa)(25~200mmHg)
c) NIBP-MEAN(2.0~24.0ka(15~180mmHg)
Maximum Mean error : ±5mmHg
Maximum Standard deviation 8mmHg
Pulse Rate Accuracy: Maximum Mean error : ±2bpm
Measure accuracy: ±2 bpm or ±5%

Ultrasonic Fetal Monitor UFM-1000D

FHR: Ultrasound Frequency: 1MHz 1.5MHz 2MHz ±1KHz


Ultrasound input intensity: 1.8 mW/cm2
Range: 30 bpm ~ 240 bpm
Accuracy: ±1bpm
Alarm limit & tolerance: Max: (30 ~ 240)bpm, tolerance: ±5%.
Min: (30 ~ 240)bpm, tolerance: ±5%

TOCO Pressure: Range: 0 ~ 100 units


Resolution: 1%
Zero-mode:Manul Automatic 5 10 15 20 Adjustable
Pressure tolerance: +6.7%

Maternal ECG: Lead selection: I, II, III, aVR, aVL, aVF, V


Heart rate range: 10-300bpm
Accuracy: ±1bpm or ±1%
Sweep speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50mm/s
Gain selection: × 1/4, × 1/2, ×1, ×2, ×4, Auto
Calibration: ±1 mV

NIBP measurement: Principle: Oscillometric method


Systolic 30-270mmHg
Diastolic 10-200mmHg

Mean 20-220mmHg
Measurement mode: Manual/Automatic/continuous measurement
Auto-measurement cycle: 0-480mins adjustable
Other function: NIBP Trend tabulation, supplementary venipuncture function