Multi-parameter Monitor

Medzer Multi-Parameter Monitor are designed for real-time monitoring of vital parameters such as ECG, SpO2, NIBP, temperature, and respiratory rate. They have clear, user-friendly display and customizable settings. Their compact and durable design allow for easy portability across departments. With reliable, precise measurements, they are essential for hospitals, clinics, and emergency care settings. Our multi-parameter monitor ensure efficient patient management and timely intervention.

Multi-para Bedside Monitor MPPM-1000A

Display: 800 × 600 pixels screen resolution

Navigation: Selection control knob or (USB mouse/keypad control – Optional)

Printer: Thermal Printer

Paper width: 50 mm

Multi-para Bedside Monitor MPPM-1000B

Display: 12.1-inch TFT LED screen

Parameter: 3/5 Lead ECG, NIBP, SpO2, Pulse Rate, Temperature, Respiration

Navigation: Selection control knob

Dimensions: 340 × 280 × 130 mm

Multi-para Bedside Monitor MPPM-1000C

Display: 12.1-inch color TFT screen

Parameter: SpO2, ECG, NIBP, TEMP, RESP, PR


ETCO2 (optional)

SpO2: Range: 0% ~ 100%
Accuracy: ±2% at 70 ~ 100% ; <70%, undefined
Alarm Range: 50-100% and OFF
Averaging: 4,8,16

Pulse rate: Range: 30 ~ 250bpm
Accuracy: ±2bpm at 30-250bpm
Alarm Range: 30-250BPM and OFF

Multi-para Bedside Monitor MPPM-1000D

Display: 7-inch LCD display


640 × 480 pixel resolution

Parameter: 3/5 Lead ECG, NIBP, SpO2, Pulse rate, Temperature, Respiration

Navigation: Selection control knob

Memory: 48 hours tabular and graphic trends & data storage

Multi-para Bedside Monitor MPPM-1000E

Display: 7 inches High brightness color LED display

Navigation: Selection control knob

Multi-para Bedside Monitor MPPM-1000F

Display: 12.1-inch (800 x 600 pixel) color TFT LCD

Parameter: 3/5 Lead ECG, NIBP, SpO2, Pulse Rate, Temperature, Respiration

SpO2: Range: 0% ~ 100%

Pulse rate: Range: 30 ~ 250bpm

Multi-para Bedside Monitor MPPM-1000G

Display: 7-inch high-brightness TFT

Parameter: 5-lead ECG, Dual TEMP, SpO2, NIBP

SpO2: Range: 0% ~ 100%

NIBP: 10 mmHg ~270 mmHg

Multi-para Bedside Monitor MPPM-1000H

Display: 12.1-inch screen, wide angle of view, TFT color screen

Parameter: ECG, SpO2, RESP, NIBP, TEMP

SpO2: Range: 0% ~ 100%


Precision: ±2% (70% ~ 100% )
Alarm range: 0% ~100%, upper and lower limit can be adjusted

NIBP: Adult: Systolic pressure: 40 ~ 270 mmHg


Diaslolic pressure 10 ~ 215 mmhg
Mean pressure 20 ~ 235 mmHg
Pediatric: Systolic pressure: 40 ~200 mmHg
Diaslolic pressure 10 ~150 mmHg
Mean pressure 20 ~ 165 mmHg

Multi-para Bedside Monitor MPPM-1000I

ECG: ±0.5mVp to 5mVp, ≥10MΩ, 0.05 to 150Hz (Diagnostic) 0.5 to 40Hz (Monitoring) 1 to 20Hz (Operation), ≥90dB (Diagnostic) ≥105dB (Monitoring & Operation), ×1/8, ×1/4, ×1/2, ×1, ×2, ×4, Auto, 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s, 15 to 350 bpm, ±1% or ±1 bpm

Respiration: Adult: 0 rpm to 120 rpm Paediatric and neonate: 0 rpm to 150 rpm, Adult: 7 rpm to 120 rpm Paediatric/neonate: 7 rpm to 150 rpm

SpO2: Dual wavelength optical method, 0% to 100%, 70% to 100%, 30 to 250 bpm, ±2 bpm, As low as 0.3%

NIBP: Oscillometric method, <30 seconds (adult cuff), 25 to 290 mmHg (Adult) 25 to 240 mmHg (Paediatric) 25 to 140 mmHg (Neonate), 10 to 25 mmHg (Adult) 10 to 200 mmHg (Paediatric) 10 to 115 mmHg (Neonate), 15 to 260 mmHg (Adult) 15 to 215 mmHg (Paediatric) 15 to 125 mmHg (Neonate), Mean difference: ±5 mmHg Standard Deviation: 8mmHg, Manual, Auto, STAT, Multi-cycle mode, 1 to 480 minutes

Multi-para Bedside Monitor MPPM-1000J

ECG: ±0.5mVp to 5mVp, ≥10MΩ, Diagnostic: 0.05 to 150Hz, Monitoring: 0.5 to 40Hz, Operation: 1 to 20Hz, Diagnostic: ≥90dB, Monitoring & Operation: ≥105dB, ×1/4, ×1/2, ×1, ×2, ×4 and auto, 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s, 15 to 350 bpm, ±1% or ±2 bpm

Respiration: 0 to 120 rpm, ±5% or ±2 rpm

SpO2: Dual-wavelength optical method, 0% to 100%, 70 to 100%, 30 to 250 bpm, ±2 bpm or ±2%, <0.3%

NIBP: Oscillometric method, Adult cuff: <30 seconds, Adult: 40 to 275 mmHg, Paediatric: 40 to 200 mmHg, Neonate: 40 to 135 mmHg, Adult: 10 to 210 mmHg, Paediatric: 10 to 150 mmHg, Neonate: 10 to 95 mmHg, Adult: 20 to 230 mmHg, Paediatric: 20 to 165 mmHg, Neonate: 20 to 110 mmHg, Mean difference: ±5 mmHg, Standard deviation: 8 mmHg; Manual, Auto, STAT, Multi-cycle mode, 1 to 480 minutes