Pulse Oximeter

Medzer Pulse Oximeter provide quick and accurate readings of blood oxygen saturation (SpO2) and pulse rate (PR). With long battery life and low-battery indicators, they ensure continuous monitoring. Their compact, user-friendly design make them easy to carry and operate. They are suitable for all ages with settings for adults, pediatrics, and neonates. The adjustable alarms for high/low SpO2 and PR, help alert users to potential health concerns. Our pulse oximeter deliver accuracy and convenience for effective health monitoring.

Handheld Pulse Oximeter

Fingertip Pulse Oximeter

Tabletop Pulse Oximeter

Fingertip Pulse Oximeter FPO-1000A

Temperature measurement time: <8 sec

Display method: TFT

Power consumption: <50 mA

Power supply: AAA battery×2

Finger Pulse Oximeter FPOX-1000A

Spo2 Measuring Range: 35 to 100%

Spo2 Accuracy: ≤ 2% range from 70 to 100%

Spo2 Low Limit: 0.9

Pulse Rate Measuring Range: 30 bpm to 240 bpm

Finger Pulse Oximeter FPOX-1000B

Spo2 Measuring Range: 70% to 100%

Spo2 Accuracy: ± 2% (80% to 100%)
±3%(70%to79%) below 70% no requirement

Resolution: 0.01

Pulse Rate Measuring Range: 30 bpm to 250 bpm

Handheld Pulse Oximeter POX-1000A

Parameter: SpO2, Pulse

SpO2 Measurement: 0 to 100 %

PR Measurement: 0 to 250 bpm

Construction: Silicon rubber shell protection and stable bracket for table usage

Handheld Pulse Oximeter POX-1000B

Parameter: SpO2, Pulse

SpO2 Measurement: 35% to 99% Accuracy: ±2% at 70% to 99%

PR Measurement: 30 bpm to 255 bpm
Accuracy: ±2 % for Normal

Construction: Silicon rubber shell protection and stable bracket for table usage

Handheld Pulse Oximeter POX-1000C

Parameter: SpO2, Pulse Rate

SpO2Measurement: 0 % to 100 %
Accuracy level: At 70 % to 100 % (±2 % for Normal), (±3 % for Low perfusion)
At < 70 %, undefined

PR Measurement: 30 bpm to 250 bpm
Accuracy: ±2 bpm for Normal, ±1 bpm for Low perfusion

Display: 2.8-inch TFT LCD screen

Handheld Pulse Oximeter POX-1000D

Parameter: SpO2, TEMP, PR & PLETH

SpO2 Measurement: 0% to 100%
Resolution:1 %
Accuracy: 70% to 99%: ±2 %

PR Measurement: 0 bpm to 250 bpm
Resolution:1 bpm
Accuracy: ± 2 bpm

TEMP: Range: 0 ℃ to 50 ℃
Resolution: 0.1℃
Accuracy: ± 0.2℃

Handheld Pulse Oximeter POX-1000E

Parameter: SpO2, PR, ETCO2 and RESP

SpO2 Measurement: 0 to 100 %

PR Measurement: 35 bpm to 254 bpm

RESP: 3 bpm to 120 bpm

Handheld Pulse Oximeter POX-1000F

Parameter: SpO2, PR, ETCO2, FiCO2 and RESP

SpO2 Measurement: 20% to 100%

PR Measurement: 25 bpm to 250 bpm
Accuracy : ± 2 bpm

FiCO2: 0 to 15 %
Accuracy: ± (0.2 Vol % + 2% reading at (0 to 5%)
Accuracy: ± (0.3 Vol % + 4% reading at (5 to10%)

Handheld Pulse Oximeter POX-1000G

Parameter: SpO2, PR

SpO2 Measurement: 0% to 100%

PR Measurement: 30 bpm to 235 bpm

Display: 2.4 inch TFT screen

Handheld Pulse Oximeter POX-1000H

Parameter: SpO2, Pulse Rate, Perfusion Index

SpO2 Measurement: 0 to 100%
Resolution: 1%
Accuracy: (>=70%)

Perfusion Index: 0 to 100%
Resolution: 1%
Accuracy: (>=70%)

PR Measurement: 50 bpm to 120 bpm

Tabletop Pulse Oximeter TPO-1000A

Monitoring parameters: SpO2, Pulse rate and temperature

Channel: 1

Signal socket: SpO2, Temp and adapter

SpO2: 0 to 100%, ±2% (90 to 99%); ±3% (70 to 89%); unspecified (<70%), 0.01