Medzer Surgical Cautery are designed for precise tissue cutting and coagulation during surgery. They are built with durable materials making them reliable and easy to maintain in a clinical setting. Their user-friendly interface ensure ease of operation and safety. With adjustable power settings, they provide versatility across both minor and major surgeries. Our surgical cautery ensure improve surgical efficiency and patient safety.
Modes: Pure cut
Working Frequency: 3.8 MHz
Electrode:
Electrode | Resusable Bipolar Forceps | Resusable Fine Electrode | Disposable LEEP Electrode |
Qty | 1 | 7 | 5 |
Power Supply: 110 V / 220 V ± 10 V, 60 Hz/ 50 Hz ±1 Hz Power rating : 140 W
Modes:
Mode | Bipolar coagulation | Bipolar cut |
Power | 1-120W | 1-120W |
Load | 200Ω | 200Ω |
Working Frequency: 1.02 MHz
Electrode:
Electrode | Bipolar Forceps | Bipolar cut pencil |
Qty | 1 | 1 |
Power Supply: 220V ± 22V (110 V ± 11 V) 50 Hz ± 1 Hz
Modes:
Pure cut or cut | Blend 1 | Blend 2 | Blend 3 | Desiccate | Fulgurate or Coag. | Spray | Bipolar |
5 W ~ 300 W (Up to 5 W ~ 400 W) | - | - | - | - | 5 W ~ 150 W | - | 2 W ~ 70 W |
Working Frequency: 512 kHz ± 5% kHz
Device classification: Class I,Type CF
Leakage currents (GND): Less than 0.5mA
Modes:
Mode | Mono-polar Pure cut | Mono-polar Blend | Mono-polar Spray Coag | Mono-polar Forced Coag | Bipolar Coagulation |
Power | 1W ~ 300W | 1W ~ 200W | 1W ~ 80W | 1W ~ 120W | 1W ~ 50W |
Load | 800Ω | 800Ω | 800Ω | 800Ω | 200Ω |
Working Frequency: 512 kHz
Electrode:
Electrode | ESU Pencil | Bipolar Forceps |
Qty | 5 | 1 |
Power Supply: 220 V ± 22 V, 50Hz ± 1Hz (110 V ± 11 V, 60 Hz)
Modes:
Mode | Pure Cut | Blend 1 | Blend 2 | Blend 3 | Coagulation 1 | Coagulation 2 | Coagulation 3 | Bipolar 1 | Bipolar 2 |
Power | 350W | 250W | 200W | 200W | 200W | 200W | 100W | 70W | 70W |
Load | 500Ω | 500Ω | 500Ω | 500Ω | 500Ω | 500Ω | 500Ω | 150Ω | 150Ω |
Working Frequency: 512 kHz ± 5% kHz
Leakage currents (GND): Less than 50 μA
Leakage currents through patient: Less than 50 μA
Modes: Pure cut
Working Frequency: 512 kHz ± 5% kHz
Device classification: Class I,Type BF
Electrode:
Electrode | ESU Pencil |
Qty | 2 |
Modes:
Mode | Bipolar Coagulation 1 | Bipolar Coagulation 2 |
Power | 1 W ~ 80 W | 1 W ~ 80 W |
Load | 100 Ω | 100 Ω |
Working Frequency: 1000 kHz
Electrode:
Electrode | Reusable Bipolar Forceps |
Qty | 1 |
Power Supply: 110 V / 220 V , 60 Hz/ 50 Hz
Modes:
Mode | Pure Cut | Blend 1 | Blend 2 | Standard Coag | Spray Coag | Bipolar Cut | Bipolar Coag |
Power | 0 W ~ 300 W | 0 W ~ 250 W | 0 W ~ 200 W | 0 W ~ 100 W | 0 W ~ 70 W | 0 W ~ 100 W | 0 W ~ 70 W |
Load | 300 Ω | 300 Ω | 300 Ω | 300 Ω | 300 Ω | 50 Ω | 50 Ω |
Working Frequency: 500 kHz
Electrode:
Electrode | Electrosurgical Pencil | Disposable Bipolar Pad |
Quantity | 2 | 1 |
Power Supply: 110 V, 50 Hz / 60 Hz
Modes:
Mode | Pure Cut | Blend 1 | Blend 2 | Standard Coag | Spray Coag | Bipolar Cut | Bipolar Coag |
Power | 0 W ~ 400 W | 0 W ~ 250 W | 0 W ~ 200 W | 0 W ~ 100 W | 0 W ~ 70 W | 0 W ~ 100 W | 0 W ~ 70 W |
Load | 300 Ω | 300 Ω | 300 Ω | 300 Ω | 300 Ω | 50 Ω | 50 Ω |
Working Frequency: 500 kHz
Electrode:
Electrode | Electrosurgical Pencil | Disposable Bipolar Pad |
Quantity | 2 | 1 |
Power Supply: 110 V, 50 Hz / 60 Hz
2025 © All Rights Reserved by Medzer.com