Dual Channel Syringe Pump DCSP-1000H is a portable, lightweight medical device delivering precise medication dosage. Consists of a long-wear Lithium Polymer battery that lasts up to 6 hours. Delivers the dosage with an accuracy of ±2%. Comes with an automatic recognition of the syringe type and size. Features numeric buttons, rotatable clamp, alarms and night mode for a great experience.

Specifications :

Infusion Mode Rate Mode, Time Mode, Weight Mode, Intermittent Mode, TIVA Mode, Drug Library, Program Mode, TPN Mode, Sequential Mode, Dose Mode, Loading Dose Mode, Micro Mode
Applicable infusion set Various brands of sterile syringes: 5ml, 10ml, 20ml, 30ml, 50ml/60ml
Accuracy ±2%
Infusion rate 5ml syringe: 0.1 – 150ml/h 10ml syringe: 0.1 – 300ml/h 20ml syringe: 0.1 – 600ml/h 30ml syringe: 0.1 – 900ml/h 50ml syringe: 0.1 – 1800ml/h Increment at 0.01ml/h
VTBI (0 – 9999.99) ml
Volume infused 0 – 9999.9 ml
KVO rate (0, 0.10 – 10.0) ml/h
BOLUS rate 5ml syringe: 0.1 – 150ml/h 10ml syringe: 0.1 – 300ml/h 20ml syringe: 0.1 – 600ml/h 30ml syringe: 0.1 – 900ml/h 50ml syringe: 0.1 – 1800ml/h Increment at 0.01ml/h
Occlusion pressure 13 levels
History record 1200
Power consumption 35VA
Battery Li-Polymer 7.4V 19000mAh
Stack expandable 2 to 6 pumps
Operating conditions
Temperature 5ºC – 40 ºC
Relative humidity 10 – 85%
Atmospheric pressure 86.0kPa – 106.0kPa
Storage conditions
Temperature 20ºC – +45 ºC
Relative humidity 10 – 95%
Atmospheric pressure 50.0kPa – 106.0kPa
Transport conditions
Temperature 20ºC – 60 ºC
Relative humidity 10 – 95%
Atmospheric pressure 50.0kPa – 106.0kPa
Features :
  • Facilitates effortless transferring and moving of the device due to its compact size
  • Designed with user-friendly numeric key buttons for fast programming
  • Incorporated with audible and visual alarms for quickly identifying the issues
  • Capable of accommodating syringe sizes ranging from 5ml to 60ml
  • Allows to turn off the key’s sound and indicating light for peaceful nighttime
  • The graphic pressure indicator displays the occlusion rate in advance to prevent potential risks
  • The infusion flow rate has an accuracy of ±2%, and it can go as low as 0.1ml/h
Applications :

Dual Channel Syringe Pump is widely used in Intensive Care Units (ICUs), Patient-Controlled Analgesia (PCA), Neonatal and Paediatric Care, Anaesthesia Delivery, and Cardiac Care.