Medical Equipment Expert
Hemodialysis Machine HDM-1000E offers a selectable dialysis fluid flow range from 100 mL/min to 800 mL/min. Equipped with a display screen that provides operators with essential treatment data, system status, alerts, and controls. It regulates fluid removal during dialysis to maintain hydration and balance, following preset parameters. Our machine supports ultrafiltration rates from 0 to 4000 mL/h, with an accuracy of ± 1%. It features backup power for the blood pump in case of power failure.
Specifications
Dialysis Fluid Flow Range | 100 mL/min to 800 mL/min (Selectable) |
---|---|
Dialysis Fluid Temperature | 34.0℃ to 40.0℃ (Selectable) |
Dialysis Fluid Conductivity Range | 12 to 16 mS/cm at 25℃ |
Dialysis Fluid Conductivity Accuracy | ± 0.1 mS/cm |
Ultrafiltration Rate | 0 mL/h to 4000 mL/h |
Ultrafiltration Accuracy | ± 1% |
Ultrafiltration Factor | unlimited |
Ultrafiltration Parameters Displayed | UF goal, UF time, UF rate, UF volume |
Extracorporeal Arterial Pressure | Display Range: -380 mmHg to +400 mmHg Accuracy: ± 10 mmHg Resolution: 1 mmHg |
Extracorporeal Venous Pressure | Display Range: -180mmHg to +600 mmHg Accuracy: ± 10 mmHg Resolution: 1 mmHg |
Transmembrane Pressure | Display Range: -180mmHg to +600 mmHg Accuracy: ± 20 mmHg Resolution: 1 mmHg |
Blood Flow Range | 30 to 600ml/min in 8 mm bloodline system |
Blood Flow Accuracy | ± 10% |
Heparin Pump Syringe Size | 10, 20, 30, 50 ml |
Heparin Pump Delivery Range | 0 ml/h to 10 ml/h |
Heparin Pump Bolus Function | Maximum 20 ml per bolus |
Acid Concentration Range | 125 to 150 mmol/L |
Acid Concentration Mixing Ratio | 1 part acid to 34 parts water 4 (others ratio possible) |
Bicarbonate Concentration Range | -8 to +8 mmol/L |
Bicarbonate Concentration Mixing Ratio | 1 part bicarbonate to 27.6 parts water (others ratio possible) |
Blood Leak Detector Sensitivity | ≤ 0.35 mL blood/min with HCT of 32% |
Water Inlet Temperature | 5℃ and 32℃ |
Water Inlet Pressure | 1.5 to 6.0 bar |
Maximum Drain Height | 1m |
Supply Pressure | 0 to 2 m |
Disinfection Program Rinse | Temperature: 30℃ to 60℃ Flow rate: 300 mL/min to 800 mL/min |
Disinfection Program Hot Rinse | Temperature: 30℃ to 85℃ Flow rate: 300 mL/min to 800 mL/min |
Disinfection Program with Chemical | Temperature: 30℃ to 85℃ Flow rate: 300 mL/min to 800 mL/min |
Current | 10A |
Power Supply | AC220V±10%, 47-63HZ |
Dimensions (H × W × D) | 1380 × 380 × 400 mm |
Weight | 88 kg |
Features
Self-checking function
Double-needle dialysis
Multidetector
Includes heparin, air bubble, and rolling blood pump
Monitors and records various parameters
Automatic disinfection cleaning program
Standard Accessories
Applications
Medzer Dialysis Machine are engineered for efficient and safe blood purification. They feature an intuitive user interface for easy operation and precise control. Advanced filtration technology maximize toxin removal while maintaining patient comfort. Their compact design save space, while robust construction ensure long-term reliability. They also ensure accurate monitoring of vital parameters throughout the treatment process. Our dialysis machine optimize patient comfort and deliver effective dialysis treatment with consistency.
2024 © All Rights Reserved by Medzer.com