Syringe Size | 5 ml, 10 ml, 20 ml, 30 ml, 50 ml, 60ml |
Applicable Syringe | Compatible with syringe of any standard |
VTBI |
0.1 ml ~ 9999.9 ml 0.1 ml increment |
Linear Flow-rate | |
Flow Rate |
50 ml (60 ml): 0.1 ml/h ~ 2000.0 ml/h (0.1 ml/h or 1 ml/h step) 30m l: 0.1 ml/h-1200.0 ml/h (0.1 ml/h or 1 ml/h step) 20 ml: 0.1 ml/h-800.0 ml/h (0.1 ml/h or 1 ml/h step) 10 ml: 0.1 ml/h-400.0 ml/h (0.1 ml/h or 1 ml/h step) 5 ml: 0.1 ~ 200 ml/h (0.1 ml/h or 1 ml/h step) (Programmable 0.01 ml/h ~ 9999.9 ml/h) |
Bolus Rate | |
Bolus speed bubble volume | |
Noise | |
Dose Rate (Speed) |
5 ml: 0.1 ~ 200 ml/h 10 ml: 0.1 ~ 400 ml/h 20 ml: 0.1 ~ 800 ml/h 30 ml: 0.1 ~ 1200 ml/h 50 ml(60 ml): 0.1 ~ 2000 ml/h Automatic/Manual bolus |
Injection Pressure | |
Purge Rate |
50 ml(60 ml): 1500.0 ml/h 30 ml: 1200.0 ml/h 20 ml: 800.0 ml/h 10 ml: 400.0 ml/h 5 ml: 200 ml/h Programmable and adjustable |
Safety Classification | |
Anti-Bolus | |
Display | |
Sensor | |
PCA function | |
Accuracy | |
Infusion Mode | |
KVO Rate | 0.1 ml/h ~ 5.0 ml/h, Programmable and adjustable |
Alarms |
Syringe holder loose, Syringe Plunger dislodged, Syringe flange Insertion error Infusion complete, Syringe near empty, Occlusion Rate abnormal, Syringe empty, Syringe not calibrated Battery empty, No battery, No action, Battery low |
Drug Library |
10 categories of drugs 1030 drug listing 17 dose units |
Occlusion |
LOW (60(±15) kPa) MED (90(±15) kPa) HIGH (120(±15) kPa) |
Configuration | |
Memory Log | 5000 events stored |
Rate Mode | |
Body Weight Mode |
Volume: 0.1-999.9ml(0.1ml step) Drug Mass: 0.1-999.9mg 0.1mg step) Dose: 0.001-9999ug/kg/min(0.001ug/kg/min step) Weight: 0.1-300kg(0.1kg the least step) Dose unit: 18 units available |
Time Mode |
VOL: 0.1 ml ~ 9999.9 ml (0.1 ml step) TIME: 00:01 min ~ 99:59 min (1 min step) |
Time | |
Network Interface | RS-232 |
Waterproof level | |
Power Supply, AC | AC: 100 V ~ 240 V( +/-10%), 50/60Hz |
Battery | DC Power supply: 12~15V, power>15W; Built-in Lithium Battery: Rechargeable, 11.1V, 2000mAh. |
Battery Life | 12 hours of continuous operation |
Working Temperature | 5℃ ~ 40℃ |
Relative Humidity | |
Atmospheric Pressure | |
Dimensions | 240 × 150 × 117 mm |
Weight | 2 kgs |
Optional |
✓ Large LCD display, brightness adjustability
✓ Compatible with various syringes brands
✓ DPS dynamic pressure display
✓ Stackable to be the maximum 8 channels
✓ High accuracy ± 2% after calibration
✓ Five work modes: Rate mode, Time mode, Dose mode, Sequential mode and Drug library mode
✓ Manual or Automatic Bolus / Purge/ KVO function
✓ Vertical & Horizontal mounting clamp
✓ Anti-bolus system to reduce significantly after occlusion sudden release
✓ 5000 events stored can be reviewed and downloaded
2025 © All Rights Reserved by Medzer.com