Biphasic Defibrillator BDFM-1000E is multi-parameter device with voice alarm. It uses biphasic wave form to measure the selected parameters. Equipped with user friendly automated external defibrillators (AEDs) interface. Smart alarms with beeper/voice prompts to indicate shockable rhythm
Energy selection |
2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 J |
Charging time |
3 hours minimum of continuous ECG monitoring |
Display |
8-inch LCD, high resolution |
Sweep Speed |
25 mm/sec |
Defibrillator |
Waveform |
Biphasic (BTE) |
Charge Time |
Less than 7 seconds with a new fully charged battery |
Energy Display |
Monitor display indicates both selected and delivered energy |
Electrode impedance measurement range |
0 to 250 ohms |
|
ECG |
Lead selection |
Displayed on monitor, paddles I, II, III, AVR, AVL, AVF, V |
Lead ECG cable |
3-lead or 5-lead ECG cable paddles |
ECG size |
0.25, 0.5, 1, 1.5, 2 4 cm/mV |
Heart rate |
20 to 300BPM |
Heart rate Alarm |
On/Off displayed on monitor, user-selectable |
Smart Alarms |
Beeper/voice prompts indicate shockable rhythm |
|
SpO2 |
Measurement range |
30 to 100%, ±2% between 80% to 90%, others ±5% |
Alarm range |
User can set high limit and low limit |
Alarm accuracy |
±10% within setting values |
Alarm time accuracy |
< 12 sec
|
Pulse Oximeter |
|
|
NIBP |
Method |
Automatic oscillation |
Working mode |
Manual/automatic |
Measurement range |
Adult: 10 to 250mmHg |
|
Paediatric:10 to 200mmHg |
|
Neonatal: 10 to 135mmHg |
|
CO2 |
CO2 Range |
0 to 13% (0 to 98.8mmHg at BTPS) |
CO2 accuracy |
< 5.0% CO2 (± 3 mmHg at BTPS)
|
Breath Rate |
3 to 60 BPM |
Measurement accuracy |
±1BPM |
|
Pacemaker |
Pulse type |
Rectangular, constant current |
Pulse amplitude |
0 to 180 mA, ± 10% or 5 mA |
Pacing Rate |
Variable from 30 ppm to 180 ppm ±1.5% |
Multi-Function Electrode |
Multipurpose defibrillation/pacing electrode |
Pause |
Pacing pulse frequency reduced by a factor of 4 when activated |
|
Printer |
Paper |
50 mm thermal |
Speed |
2.5mm/sec 25mm/sec 50mm/sec |
Printing Method |
High-resolution thermal print head |
Print-out Modes |
Manual or automatic |
On/Off Control |
Front panel and paddle |
Automatic Function |
9-seconds recording initiated by alarm activatio |
|
AED Mode |
AED Function |
Auto analyze and charge x3 with programmable auto energy level selection screen prompts and voice prompts |
Shockable Rhythms |
Ventricular fibrillation with amplitude ≥ 200 µV ventricular Tachycardia with rates ≥ 140 bpm |
|
QRS complex wave duration ≥ 140 m |
Charge Control |
Control on device front panel press key on paddle |
Prompts |
Voice and visual prompts |
Manual Mode |
Synchronizes defibrillator pulse to patient’s R-wave. “SYNC” message displayed on monitor |
Battery |
Rechargeable Ni-MH battery 12V |
Packaging dimensions |
330 × 318 × 135 mm |
Weight |
4.95 kg |
Features :
- Cable paddles to monitor ECG
- Automatic or manual operation
- Equipped with pacemaker type VVI
- Synchronizes defibrillator pulse to patients R-wave
- Integrated with high resolution thermal printer
- 8-inch LCD display with high resolution
- Smart alarms with voice prompts to indicate shockable rhythm
- Micro SD card for expanding storage capacity
- Stores data for 65 hours of all the measured parameters
Applications :
Biphasic defibrillators are commonly used in hospitals, emergency medical services (EMS), and other healthcare settings