Anesthesia System MAS-1000A is a medical device used to administer general anesthesia to patients undergoing surgical procedures or other medical interventions. Vaporizers convert liquid anaesthetic agents (Halothane, Enflurane, Isoflurane, Sevoflurane) into precise inhalable vapor concentrations for patients. Ventilators can deliver breaths at specific tidal volumes and rates, ensuring adequate ventilation. Equipped with pressure gauge to measure and display the pressure of various gases.

Specifications

Gas source O2, N2O, AIR
Pressure 280 kPa to 600 kPa
Parameters monitored
Frequence(Freq) 0 /min to 100 /min
Tidal volume (Vt) 0 mL to 2000 mL
MV 0 L/min to 100 L/min
Oxygen concentration 0 % to 100%
Ventilation mode IPPV, V-A/C, P-A/C, V-SIMV, P-SIMV, PCV-PC, PCV-VG, PSV, SIGH, MANUAL
Flowmeter O2- 0.1 to 10 L/min
N2O- 0.1 to 10 L/min
AIR- 0.1 to 10 L/min
Rapid oxygen supply 25 L/min to 75 L/min
Tidal volume (Vt) 0, 20 mL to 1500 mL
Frequency(Freq) 1 /min to 100 /min
I/E 4:1 ~ 1:8
PEEP 0 cmH2O to 30 cmH2O
Pressure triggering sensitivity (PTr) -20 cmH2O to 0 cmH2O
Flow trigger sensitivity (FTr) 0.5 L/min to 30 L/min
Pressure control (PC) 5 cmH2O to 70 cmH2O
SIGH 0 (off) 1/100 to 5/100
Apnea ventilation OFF, 5s - 60s
Pressure limit 10 cmH2O to 100 cmH2O
Waveform display P-T (pressure-time)
F-T (flow-time)
V-T (volume-time)
ETCO2-T(ETCO2-time)
P-V loop (pressure-volume loop)
P-F loop (pressure-flow loop)
F-V loop (flow-volume loop)
AC power failure alarm Power failure or no connection
Internal battery backup low voltage alarm < 10.2 ± 0.3 V
No tidal volume ≤ 5 mL within 6 s
High oxygen concentration alarm 19 % to 100 %
Low oxygen concentration alarm 18 % to 99 %
High airway pressure alarm 20 cmH2O to 100 cmH2O
Low airway pressure alarm 0 cmH2O to 20 cmH2O
High minute volume alarm Adult- 5 L/min to 20 L/min
Low minute volume alarm Paed- 1 L/min to 15 L/min, 0 to 10 L/min
Continuous pressure alarm PEEP+1.5 kPa) over 16 s
Suffocation warning 5 s to 60 s no spontaneous ventilation
Maximum limited pressure ≤12.5 kPa
Power supply 100 to 240 V 50/60 Hz
Power consumption 80 VA
Packaging dimensions (L × W × H) 920 × 970 × 1380 mm
Net weight 87.5 Kg
Gross weight 155 Kg

Features

High precision flowmeter

Bellow APL valve regulates and releases excess pressure during exhalation

10.4 inches TFT LCD screen displays parameters

Integrated breathing circuit design ensures easy operation

3-level alarm system with audio and visual alert mechanism

Four stationary casters with built-in locking mechanisms

Automatic decompression ensures safety while using Anaesthesia System

Built-in backup battery provides emergency power supply

Optional Accessories

Etco2


AG module
Anaesthetic Gas Scavenging System(AGSS)
Yoke

Applications

Anesthesia systems are used to induce unconsciousness or numbness during surgeries, diagnostic procedures, emergencies, critical care, and research