Anesthesia System MAS-1000A supports multiple gas sources including O2, N2O, and AIR, with a pressure range from 280 kPa to 600 kPa. It monitors critical parameters such as frequency, tidal volume, minute volume, and oxygen concentration. It offers various ventilation modes and rapid oxygen supply ranging from 25 to 75 L/min. It features alarms for power failure, low battery, no tidal volume, oxygen concentration, airway pressure, minute volume, continuous pressure, and suffocation. Our system’s built-in backup battery guarantees uninterrupted operation during power outages.

Specifications

Gas Source O2, N2O, AIR
Pressure 280 kPa to 600 kPa
Parameters Monitored Frequency (Freq): 0 /min to 100 /min
Tidal volume (Vt): 0 mL to 2000 mL
MV: 0 L/min to 100 L/min
Oxygen concentration: 0 % to 100%
Ventilation Mode IPPV, V-A/C, P-A/C, V-SIMV, P-SIMV, PCV-PC, PCV-VG, PSV, SIGH, MANUAL
Flowmeter O2- 0.1 to 10 L/min
N2O- 0.1 to 10 L/min
AIR- 0.1 to 10 L/min
Rapid Oxygen Supply 25 L/min to 75 L/min
Tidal Volume (Vt) 0, 20 mL to 1500 mL
Frequency (Freq) 1 /min to 100 /min
I/E 4:1 to 1:8
PEEP 0 cmH2O to 30 cmH2O
Pressure Triggering Sensitivity (PTr) -20 cmH2O to 0 cmH2O
Flow Trigger Sensitivity (FTr) 0.5 L/min to 30 L/min
Pressure Control (PC) 5 cmH2O to 70 cmH2O
SIGH 0 (off) 1/100 to 5/100
Apnea Ventilation OFF, 5s to 60s
Pressure Limit 10 cmH2O to 100 cmH2O
Waveform Display P-T (pressure-time)
F-T (flow-time)
V-T (volume-time)
ETCO2-T(ETCO2-time)
P-V loop (pressure-volume loop)
P-F loop (pressure-flow loop)
F-V loop (flow-volume loop)
AC Power Failure Alarm Power failure or no connection
Internal Battery Backup Low Voltage Alarm < 10.2 ± 0.3 V
No Tidal Volume ≤ 5 mL within 6 s
High Oxygen Concentration Alarm 19 % to 100 %
Low Oxygen Concentration Alarm 18 % to 99 %
High Airway Pressure Alarm 20 cmH2O to 100 cmH2O
Low Airway Pressure Alarm 0 cmH2O to 20 cmH2O
High Minute Volume Alarm Adult- 5 L/min to 20 L/min
Low Minute Volume Alarm Paed- 1 L/min to 15 L/min, 0 to 10 L/min
Continuous Pressure Alarm PEEP+1.5 kPa over 16 s
Suffocation Warning 5 s to 60 s no spontaneous ventilation
Maximum Limited Pressure ≤12.5 kPa
Power Supply 100 to 240 V 50/60 Hz
Power Consumption 80 VA
Packaging Dimensions (L × W × H) 920 × 970 × 1380 mm
Net Weight 87.5 Kg
Gross Weight 155 Kg

Features

3-level alarm system with audio and visual alerts

Integrated breathing circuit design

Built-in locking mechanisms

Automatic decompression

Multiple waveforms display

10.4-inch TFT LCD screen

Optional Accessories

EtCO2
AG Module
Anaesthetic Gas Scavenging
System (AGSS)
Yoke

Applications

Our Anesthesia System administers general anesthesia to patients undergoing surgical procedures or other medical interventions.