Medical Equipment Expert

info@medzer.com

whatsapp
12 Channel ECG Machine TECG-1000A

12 Channel ECG Machine TECG-1000A

12 Channel ECG Machine TECG-1000A is a sophisticated medical device used to measure the heart's electrical activity through 12 distinct leads. Real-time monitoring allows you to monitor ECG signals continuously on a 10-inch LCD display. Thermal printing process employed to print waveforms for interpretation and documentation. Stores 200 copies for easy analysis and review. Continuous monitoring delivers immediate feedback to healthcare professionals during critical procedures.

Specifications

Lead 12 Standard 
LCD Display 1024×600
Patient Current Leakage <10uA
CMRR >100dB
Input dynamics ±500 mV
Input impedance ≥50Mohm
Input circuit current ≤0.1μA
Frequency response 0.05 to 150HZ
Recording sensitivity 1.25mm,2.5mm,5mm,10mm,20mm,40mm/mV±2%
Data acquisition 12 bits; 8000 samples/sec
Fuse Specification Φ5 × 20mm 3.15A 250V
Patient Cable Standard 10 core
Time Constant ≥3.2s
Noise Level ≤15μVp-p
Thermal paper 216mm×20M thermal paper in Z-fold packers
Print channels 12 channels, Rhythem lead selectable
Printing speed 5; 6.25; 10; 12.5; 25; 50mm/s ± 3%
Printing system Thermal printer ≥8dot Vertical ≥40 dot
Printing Output 3+3 channel,6 channel, 6+1 channel, 12 channel,12+1 channel
Filter Muscle filter:(25Hz/35Hz/45Hz/75Hz/100Hz, -3dB) AC filter: (50Hz or 60Hz, -20dB) Drift filter: (0.5Hz, -3dB)
Calibration Voltage 1mV±2%
Power Supply 220V±10%, 50Hz±2%, 75VA 14.8V 4400mA 
Dimensions 44 ×41 × 24 cm
Net Weight   3.9kg                                                              
Gross Weight 6.4kg

Features

Featured a user-friendly 10 inches touchscreen interface

Equipped with a USB and RS232 Interface

A Binary-mode ECG machine able to interpret and guide the acquisition process

Input circuits are substantiated with Floating, Defibrillation protection

Capable of performing Manual, Auto and Arrhythmia Analysis modes

Selectable Rhythm Lead and 12 Channels are Print Channels

Digital filters terminate the AC, EMG, baseline drift interference

With built-in memory and external SD card support, it can store 200 reports

Set up with a rechargeable Li-ion battery with 2 hours of continuous use

Lead-off detection is an indicator

IEC, Class I, type CF are safety standards

Presentation, review, and re-printing of the report

Standard Accessories

Chest Electrodes Adult- (set of six) 2Quantity
Chest Electrodes Paediatric- (set of six) 2Quantity
Chest electrodes Clip type for Neonatal (Set of six)2Quantity
Limb Electrodes (set of 4) 2Quantity
Thermal Paper A4 Size for 500 patients 1Quantity

Applications

It is ideal for diagnostic techniques that can be used to identify a variety of cardiac disorders, such as coronary artery disease, cardiac arrhythmia, and cardiomyopathy. It is widely used in clinical settings, such as hospitals, clinics, and ambulances.

Buy Now :- 12 Channel ECG Machine TECG-1000A